WarmlyYours ERT120-1.5x18 Manuel d'instructions

Naviguer en ligne ou télécharger Manuel d'instructions pour Accessoires pour motos WarmlyYours ERT120-1.5x18. WarmlyYours ERT120-1.5x18 Circuit Check Instructions Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 2
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 0
SHEATH
CORE
CORE
Black Inner Lead
Yellow (120V)
or Red (240V)
Inner Lead
Copper
Ground Sheath
BLACK
GREEN
(Sheath)
RED
SHEATH
CORE
CORE
Black Inner Lead
Yellow (120V)
or Red (240V)
Inner Lead
Copper
Ground Sheath
BLACK
GREEN
(Sheath)
RED
Paperclip
TESTING THE CIRCUIT CHECK
1. LAY OUT THE WARMLYYOURS WARMING SYSTEM ROLL(S)
Lay out the roll(s) in accordance with the design layout and instructions provided by WarmlyYours.
2. TEST THE CIRCUIT CHECK DEVICE
1
Before connecting any wires, install the batteries in the device and turn it "on" and "off" to test
the alarm. The unit should alarm when disconnected and powered “on”.
After confirming that the alarm is in good working order, connect the wires as follows:
- Connect Black inner conductor core wire to the Black terminal.
- Connect 2nd inner conductor core wire to the Red terminal.
THERE ARE TWO WAYS OF DOING THE NEXT STEP:
2.1 Split the ground sheath in two, connect one half of the ground sheath to the green terminal,
turn on the Circuit Check and touch the other half of the ground shealth to one of the inner
conductor wires;
2.2 Install the entire ground into the green terminal. Turn on unit and use a paper clip as a bridge
between the ground wire and either one of the inner conductors.
Either method should activate the alarm. If the Circuit Check does not pass all these tests,
please call WarmlyYours Customer Service at (800) 875-5285.
Please turn over to view detailed illustrations for wiring
Tempzone to the Circuit Check
Note
1
: This device is NOT an Ohm meter. WarmlyYours requires that the roll be tested before, during and after
installation with a Digital Ohm meter.
Circuit Check Device
Testing and Installation
Installation Support •(800) 875-5285 • www.WarmlyYours.com
Vue de la page 0
1 2

Résumé du contenu

Page 1 - Circuit Check Device

SHEATH CORE CORE Black Inner Lead Yellow (120V) or Red (240V)Inner LeadCopper Ground SheathBLACKGREEN(Sheath)RED SHEATH CORE CORE Black Inner Lead Ye

Page 2

Wiring Tempzone to Circuit CheckSHEATH CORE CORE Black Inner Lead Yellow (120V) or Red (240V)Inner LeadCopper Ground SheathON OFF BLACKGREE

Commentaires sur ces manuels

Pas de commentaire